A '''current loop''' describes two different electrical [[signalling (telecommunication)|signalling]] schemes.


== Digital ==
For [[digital]] [[serial communications]] a current loop is a communication interface that uses [[electrical current|current]] instead of [[voltage]] for signaling. Current loops can be used over moderately long distances (tens of kilometres), and can be interfaced with [[optical isolator|optically isolated]] links.


Long before the [[RS-232]] standard, current loops were used to send digital data in [[Asynchronous start-stop|serial]] form for [[teleprinter]]s. More than two teletypes could be connected on a single circuit allowing a simple form of networking. Older teletypes used a 60 [[Ampere|mA]] current loop. Later machines, such as the [[ASR33]] [[teleprinter]], operated on a lower 20 mA current level and most early [[minicomputer]]s featured a 20 mA current loop interface, with an RS-232 port generally available as a more expensive option. The original [[IBM PC]] [[Serial port]] card had provisions for a 20 mA current loop. A digital current loop uses the absence of current for high (space or break), and the presence of current in the loop for low (mark).
'''Welcome!'''


The maximum [[electrical resistance|resistance]] for a current loop is limited by the available voltage. Current loop interfaces usually use voltages much higher than those found on an RS 232 interface, and cannot be interconnected with voltage-type inputs without some form of level translator circuit.
Hello, {{BASEPAGENAME}}, and [[Wikipedia:Introduction|welcome]] to Wikipedia! Thank you for [[Special:Contributions/{{BASEPAGENAME}}|your contributions]]{{#if:|, especially what you did for [[:{{{art}}}]]}}. I hope you like the place and decide to stay. Here are some pages that you might find helpful:

*[[Wikipedia:Five pillars|The five pillars of Wikipedia]]
MIDI ([[Musical Instrument Digital Interface]]) is a digital current loop interface.
*[[Wikipedia:Tutorial|Tutorial]]

*[[Wikipedia:How to edit a page|How to edit a page]]
== Analog ==
*[[Wikipedia:Article development|How to write a great article]]
Analog current loops are used where a device must be monitored or controlled remotely over a pair of conductors. Only one current level can be present at any time.
*[[Wikipedia:Manual of Style|Manual of Style]]

I hope you enjoy editing here and being a [[Wikipedia:Wikipedians|Wikipedian]]! Please [[Wikipedia:Signatures|sign]] your messages on [[Wikipedia:talk page|discussion page]]s using four [[tilde]]s (<nowiki>~~~~</nowiki>); this will automatically insert your username and the date. If you need help, check out [[Wikipedia:Questions]], ask me on {{#if:Stifle|[[user talk:Stifle|my talk page]]|my talk page}}, or ask your question on this page and then place <code><nowiki>{{helpme}}</nowiki></code> before the question. Again, welcome! <!-- Template:Welcome -->[[User:Stifle|Stifle]] [[User talk:Stifle/wizard|(talk)]] 10:30, 10 October 2008 (UTC)
''4-20 mA '''DC''''' ("four to twenty milliamp current loop"), also referred to as "process current", is an [[analog signal|analog]] [[electrical]] transmission standard for industrial [[instrumentation]] and communication. The signal is a current loop where 4 mA represents zero percent signal and 20 mA represents the one hundred percent signal.<ref name=bolton>{{cite book|title=Instrumentation and Control Systems|first=William|last=Bolton|isbn=0750664320|year=2004|publisher=[[Elsevier]]|url=http://books.google.com/books?id=X-gADDWI-NIC&pg=PA54&dq=current-loop&lr=&ei=g6-nR8SbIpXGyATdgYWRBA&ie=ISO-8859-1&sig=lnfzGGnS0wPyCjVZ-le-1KnfIB0}}
</ref> A "mA" is a [[milliampere]], or 1/1000 of an [[ampere]].

The "live zero" at 4 mA allows the receiving instrumentation to distinguish between a zero signal and a broken wire or a dead instrument.<ref name=bolton/> The feature also allows low-power instruments to be directly powered from the loop, saving the cost of extra wires. The 4-20 mA standard was developed in the 1950s and is still widely used in industry today. Benefits of the 4-20 mA convention are that it is widely used by many manufacturers, relatively low-cost to implement, and it can reject many forms of [[electrical noise]]. The inherent noise rejection of 4-20 mA allows it to be used where the transducer is located far from the measuring instrument. Cable lengths of 50 meters or more are common.

Given its analog nature, current loops are easier to understand and debug than more complicated digital [[fieldbus]]es, requiring only a handheld digital [[voltmeter]] in most situations. Using fieldbuses and solving related problems usually requires much more education and understanding than required by simple current loop systems.

Additional digital communication to the device can be added to current loop using [[HART Protocol]]. Digital process buses such as [[FOUNDATION Fieldbus]] and [[Profibus]] may replace analog current loops.

== Process-control use ==
For industrial [[process control]] instruments, [[analog signal|analog]] 4-20 mA and 10-50 mA current loops are commonly used for analog signaling, with 4 mA representing the lowest end of the range and 20 mA the highest. The key advantages of the current loop are that the accuracy of the signal is not affected by voltage drop in the interconnecting wiring, and that the loop can supply operating power to the device. Even if there is significant [[electrical resistance]] in the line, the current loop transmitter will maintain the proper current, up to its maximum voltage capability. The live-zero represented by 4 mA allows the receiving instrument to detect some failures of the loop, and also allows transmitter devices to be powered by the same current loop (called ''two-wire'' transmitters). Such instruments are used to measure [[pressure]], [[temperature]], [[flow]], [[pH]] or other process variables. A current loop can also be used to control a valve positioner or other output [[actuator]]. An analog current loop can be converted to a voltage input with a precision resistor. Since input terminals of instruments may have one side of the current loop input tied to the chassis ground (earth), analog isolators may be required when connecting several devices in series.

Taking the point of view of the source of current for the loop, devices may be classified as ''active'' (supplying power) or ''passive'' (relying on loop power). For example, a [[chart recorder]] may provide loop power to a transmitter instrument such as a pressure transmitter. The pressure transmitter modulates the current on the loop to send the signal to the strip chart recorder, but does not in itself supply power to the loop and so is passive. Another loop may contain two passive chart recorders, a passive pressure transmitter, and a 24 V battery. (The battery is the active device).
Panel mount displays and chart recorders are commonly termed 'indicator devices' or 'process monitors'.
Several passive indicator devices may be connected in series, but a loop must have only one transmitter device and only one power source (active device).

The relationship between current value and process variable measurement is set by calibration, which assigns different ranges of engineering units to the span between 4 and 20 mA. Occasionally the mapping between engineering units and current was inverted, so that 4 mA represented the maximum and 20 mA the minimum.

==Long circuits==
Analog current loops were occasionally carried between buildings by [[dry pair]]s in telephone cables leased from the local telephone company. 4-20 mA loops were more common in the days of analog telephony. These circuits require end-to-end direct current (DC) continuity. DC continuity is not available over a microwave radio, optical fiber, or a multiplexed telephone circuit connection.

Basic DC circuit theory reminds us that current is the same at all points in a circuit. It was common to see 4-20 mA circuits that had loop lengths in miles or circuits working over telephone cable pairs that were longer than ten thousand feet end-to-end. There are still legacy systems in place using this technology. In [[Bell System]] circuits, voltages up to 125V DC were employed.

==Discrete control==
Discrete control functions can be represented by discrete levels of current sent over a loop. This would allow multiple control functions to be operated over a single pair of wires. Currents required for a specific function vary from one application or manufacturer to another. There is no specific current that is tied to a single meaning. It is almost universal that 0 mA indicates the circuit has failed. In the case of a fire alarm, 6 mA could be normal, 15 mA could mean a fire has been detected, and 0 mA would produce a trouble indication, telling the monitoring site the alarm circuit had failed. Some devices, such as [[two-way radio]] remote control consoles, can reverse the polarity of currents and can multiplex audio onto a DC current.

These devices can be employed for any remote control need a designer might imagine. For example, a current loop could actuate an evacuation [[Siren (noisemaker)|siren]] or command synchronized [[traffic signals]].

===Two-way radio use===
[[Image:T1380 remote.png|thumb|right|230px|A [[Motorola]] T-1300 series [[remote control]] is built in a [[telephone]] housing. The dial is replaced with a [[Loudspeaker|speaker]] and volume control. This remote control uses a two-wire circuit to control a [[base station]].]]Current loop circuits are one possible way used to control radio [[base station]]s at distant sites. The two-way radio industry calls this type of remote control '''DC remote'''. This name comes from the need for DC circuit continuity between the control point and the radio [[base station]]. The purpose current loop remote control is to save the cost of extra pairs of wires between the operating point and the radio transceiver. Some equipment, such as the Motorola MSF-5000 base station, uses currents below 4 mA for some functions. An alternative type, the [[Tone remote]], is more complex but requires only an audio path between control point and base station. To confirm the use of the phrase "DC remote" as accurate in describing this type of device, please see <ref>{{patent|US|6950653|"Scanning tone remote adapter for land-mobile radio dispatch for use with dispersed dispatch stations"}}</ref>. The patent does not describe this tone remote but confirms the use of the phrase to describe this system of signaling.

For example, a [[Taxicab|taxi]] [[Dispatcher|dispatch]] base station might be physically located on the rooftop of an eight-story building. The taxi company office might be in the basement of a different building nearby. The office would have a remote control unit that would operate the taxi company base station over a current loop circuit. The circuit would normally be over a telephone line or similar wiring. Control function currents come from the remote control console at the dispatch office end of a circuit. In two-way radio use, an idle circuit would normally have no current flow present.

In [[two-way radio]] use, radio manufacturers use different currents for specific functions. Polarities are changed to get more possible functions over a single circuit. For example, imagine one possible scheme where the presence of these currents cause the base station to change state:
* no current means ''receive on channel 1'', (the default).
* +6 mA might mean ''transmit on channel 1''
* -6 mA might mean ''stay in receive mode but switch to channel 2''. So long as the -6 mA current were present, the remote base station would continue to receive on channel 2.
* -12 mA might command the base station to ''transmit on channel 2''.

Note that this circuit is polarity-sensitive. If a telephone company cable splicer accidentally reversed the conductors, selecting channel 2 would lock the transmitter on.

Each current level could close a set of contacts, or operate solid-state logic, at the other end of the circuit. That contact closure caused a change of state on the controlled device. Some remote control equipment could have options set to allow compatibility between manufacturers. That is, a base station that was configured to transmit with a +18 mA current could have options changed to (instead) make it transmit when +6 mA was present.

In two-way radio use, AC signals were also present on the circuit pair. If the base station were idle, receive audio would be sent over the line from the base station to the dispatch office. In the presence of a transmit command current, the remote control console would send audio to be transmitted. The voice of the user in the dispatch office would be superimposed over the DC current that caused the transmitter to operate.

==See also==
* [[Current source]] (a current loop transmitter)
* [[Current-to-voltage converter]]

==References==
<references/>
*Lipták, Béla G. ''Instrumentation Engineers' Handbook. Process Measurement and Analysis''. CRC Press. 2003. HB. ISBN 0-8493-1083-0

== External links ==
* [http://zone.ni.com/devzone/cda/tut/p/id/6940 Fundamentals, System Design, and Setup for the 4 to 20 mA Current Loop]
* [http://www.datel.com/data/meters/dms-an20.pdf 4-20 mA Current Loop Primer]
* [http://celesco.com/faq/420.htm What Voltage do I need to operate my 4...20 mA transducer?]
* [http://www.allaboutcircuits.com/vol_1/chpt_9/3.html Current signal systems]
* [http://www.maxim-ic.com/appnotes.cfm/appnote_number/1064 Designing a 4-20 mA Current Loop]
* [http://www.circuit-fantasia.com/circuit_stories/inventing_circuits/current_source/current_source_philosophy/current_source_philosophy.htm Reinventing constant current source] in eight consecutive steps
* [http://www.circuit-fantasia.com/collections/circuit-collection/circuits/old-circuits/i-to-v-old.html Current-to-voltage passive converter] - an animated flash tutorial about the passive current-to-voltage converter

[[Category:Measurement]]
[[Category:Communication circuits]]
[[Category:Electronics terms]]
[[Category:Electronics standards]]
[[Category:Serial buses]]

[[de:Stromschnittstelle]]
[[it:Current loop]]
[[nl:4-20 mA]]

Revision as of 16:22, 11 October 2008

A current loop describes two different electrical signalling schemes.

Digital

For digital serial communications a current loop is a communication interface that uses current instead of voltage for signaling. Current loops can be used over moderately long distances (tens of kilometres), and can be interfaced with optically isolated links.

Long before the RS-232 standard, current loops were used to send digital data in serial form for teleprinters. More than two teletypes could be connected on a single circuit allowing a simple form of networking. Older teletypes used a 60 mA current loop. Later machines, such as the ASR33 teleprinter, operated on a lower 20 mA current level and most early minicomputers featured a 20 mA current loop interface, with an RS-232 port generally available as a more expensive option. The original IBM PC Serial port card had provisions for a 20 mA current loop. A digital current loop uses the absence of current for high (space or break), and the presence of current in the loop for low (mark).

The maximum resistance for a current loop is limited by the available voltage. Current loop interfaces usually use voltages much higher than those found on an RS 232 interface, and cannot be interconnected with voltage-type inputs without some form of level translator circuit.

MIDI (Musical Instrument Digital Interface) is a digital current loop interface.

Analog

Analog current loops are used where a device must be monitored or controlled remotely over a pair of conductors. Only one current level can be present at any time.

4-20 mA DC ("four to twenty milliamp current loop"), also referred to as "process current", is an analog electrical transmission standard for industrial instrumentation and communication. The signal is a current loop where 4 mA represents zero percent signal and 20 mA represents the one hundred percent signal.[1] A "mA" is a milliampere, or 1/1000 of an ampere.

The "live zero" at 4 mA allows the receiving instrumentation to distinguish between a zero signal and a broken wire or a dead instrument.[1] The feature also allows low-power instruments to be directly powered from the loop, saving the cost of extra wires. The 4-20 mA standard was developed in the 1950s and is still widely used in industry today. Benefits of the 4-20 mA convention are that it is widely used by many manufacturers, relatively low-cost to implement, and it can reject many forms of electrical noise. The inherent noise rejection of 4-20 mA allows it to be used where the transducer is located far from the measuring instrument. Cable lengths of 50 meters or more are common.

Given its analog nature, current loops are easier to understand and debug than more complicated digital fieldbuses, requiring only a handheld digital voltmeter in most situations. Using fieldbuses and solving related problems usually requires much more education and understanding than required by simple current loop systems.

Additional digital communication to the device can be added to current loop using HART Protocol. Digital process buses such as FOUNDATION Fieldbus and Profibus may replace analog current loops.

Process-control use

For industrial process control instruments, analog 4-20 mA and 10-50 mA current loops are commonly used for analog signaling, with 4 mA representing the lowest end of the range and 20 mA the highest. The key advantages of the current loop are that the accuracy of the signal is not affected by voltage drop in the interconnecting wiring, and that the loop can supply operating power to the device. Even if there is significant electrical resistance in the line, the current loop transmitter will maintain the proper current, up to its maximum voltage capability. The live-zero represented by 4 mA allows the receiving instrument to detect some failures of the loop, and also allows transmitter devices to be powered by the same current loop (called two-wire transmitters). Such instruments are used to measure pressure, temperature, flow, pH or other process variables. A current loop can also be used to control a valve positioner or other output actuator. An analog current loop can be converted to a voltage input with a precision resistor. Since input terminals of instruments may have one side of the current loop input tied to the chassis ground (earth), analog isolators may be required when connecting several devices in series.

Taking the point of view of the source of current for the loop, devices may be classified as active (supplying power) or passive (relying on loop power). For example, a chart recorder may provide loop power to a transmitter instrument such as a pressure transmitter. The pressure transmitter modulates the current on the loop to send the signal to the strip chart recorder, but does not in itself supply power to the loop and so is passive. Another loop may contain two passive chart recorders, a passive pressure transmitter, and a 24 V battery. (The battery is the active device). Panel mount displays and chart recorders are commonly termed 'indicator devices' or 'process monitors'. Several passive indicator devices may be connected in series, but a loop must have only one transmitter device and only one power source (active device).

The relationship between current value and process variable measurement is set by calibration, which assigns different ranges of engineering units to the span between 4 and 20 mA. Occasionally the mapping between engineering units and current was inverted, so that 4 mA represented the maximum and 20 mA the minimum.

Long circuits

Analog current loops were occasionally carried between buildings by dry pairs in telephone cables leased from the local telephone company. 4-20 mA loops were more common in the days of analog telephony. These circuits require end-to-end direct current (DC) continuity. DC continuity is not available over a microwave radio, optical fiber, or a multiplexed telephone circuit connection.

Basic DC circuit theory reminds us that current is the same at all points in a circuit. It was common to see 4-20 mA circuits that had loop lengths in miles or circuits working over telephone cable pairs that were longer than ten thousand feet end-to-end. There are still legacy systems in place using this technology. In Bell System circuits, voltages up to 125V DC were employed.

Discrete control

Discrete control functions can be represented by discrete levels of current sent over a loop. This would allow multiple control functions to be operated over a single pair of wires. Currents required for a specific function vary from one application or manufacturer to another. There is no specific current that is tied to a single meaning. It is almost universal that 0 mA indicates the circuit has failed. In the case of a fire alarm, 6 mA could be normal, 15 mA could mean a fire has been detected, and 0 mA would produce a trouble indication, telling the monitoring site the alarm circuit had failed. Some devices, such as two-way radio remote control consoles, can reverse the polarity of currents and can multiplex audio onto a DC current.

These devices can be employed for any remote control need a designer might imagine. For example, a current loop could actuate an evacuation siren or command synchronized traffic signals.

Two-way radio use

A Motorola T-1300 series remote control is built in a telephone housing. The dial is replaced with a speaker and volume control. This remote control uses a two-wire circuit to control a base station.

Current loop circuits are one possible way used to control radio base stations at distant sites. The two-way radio industry calls this type of remote control DC remote. This name comes from the need for DC circuit continuity between the control point and the radio base station. The purpose current loop remote control is to save the cost of extra pairs of wires between the operating point and the radio transceiver. Some equipment, such as the Motorola MSF-5000 base station, uses currents below 4 mA for some functions. An alternative type, the Tone remote, is more complex but requires only an audio path between control point and base station. To confirm the use of the phrase "DC remote" as accurate in describing this type of device, please see [2]. The patent does not describe this tone remote but confirms the use of the phrase to describe this system of signaling.

For example, a taxi dispatch base station might be physically located on the rooftop of an eight-story building. The taxi company office might be in the basement of a different building nearby. The office would have a remote control unit that would operate the taxi company base station over a current loop circuit. The circuit would normally be over a telephone line or similar wiring. Control function currents come from the remote control console at the dispatch office end of a circuit. In two-way radio use, an idle circuit would normally have no current flow present.

In two-way radio use, radio manufacturers use different currents for specific functions. Polarities are changed to get more possible functions over a single circuit. For example, imagine one possible scheme where the presence of these currents cause the base station to change state:

  • no current means receive on channel 1, (the default).
  • +6 mA might mean transmit on channel 1
  • -6 mA might mean stay in receive mode but switch to channel 2. So long as the -6 mA current were present, the remote base station would continue to receive on channel 2.
  • -12 mA might command the base station to transmit on channel 2.

Note that this circuit is polarity-sensitive. If a telephone company cable splicer accidentally reversed the conductors, selecting channel 2 would lock the transmitter on.

Each current level could close a set of contacts, or operate solid-state logic, at the other end of the circuit. That contact closure caused a change of state on the controlled device. Some remote control equipment could have options set to allow compatibility between manufacturers. That is, a base station that was configured to transmit with a +18 mA current could have options changed to (instead) make it transmit when +6 mA was present.

In two-way radio use, AC signals were also present on the circuit pair. If the base station were idle, receive audio would be sent over the line from the base station to the dispatch office. In the presence of a transmit command current, the remote control console would send audio to be transmitted. The voice of the user in the dispatch office would be superimposed over the DC current that caused the transmitter to operate.

See also

References

  1. ^ a b Bolton, William (2004). Instrumentation and Control Systems. Elsevier. ISBN 0750664320.
  2. ^ US 6950653  "Scanning tone remote adapter for land-mobile radio dispatch for use with dispersed dispatch stations"
  • Lipták, Béla G. Instrumentation Engineers' Handbook. Process Measurement and Analysis. CRC Press. 2003. HB. ISBN 0-8493-1083-0

External links